Validity of Tools to Measure Physical Activity in Older Adults Following Total Knee Arthroplasty

J Aging Phys Act. 2021 Aug 1;29(4):651-658. doi: 10.1123/japa.2020-0240. Epub 2020 Dec 30.

Abstract

Few validated tools exist for measuring physical activity following total knee arthroplasty (TKA) despite the importance of returning to sufficient levels of physical activity post-TKA to achieve health benefits. This study examined the validity of two clinical measures-the Fitbit, a commercially available personal activity monitor, and the Community Healthy Activities Model Program for Seniors (CHAMPS), a self-report questionnaire-compared with a reference standard accelerometer, the SenseWearTM Armband (SWA). At 6-month post-TKA, 47 participants wore the Fitbit and SWA for 4 days and then completed the CHAMPS. Moderate-to-good correlation was observed between the Fitbit and SWA for steps (intraclass correlation coefficient [ICC] = .79), energy expenditure (ICC = .78), and energy expenditure <3 METS (ICC = .79). Poor-to-moderate correlation was observed between the CHAMPS and SWA (ICC = .43) with the questionnaire reporting lower daily energy expenditures than the SWA. Results showed that Fitbit may be a reasonable measurement tool to measure steps and energy expenditures in older adults following TKA.

Keywords: accelerometer; energy expenditure; self-report; steps.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Arthroplasty, Replacement, Knee*
  • Energy Metabolism
  • Exercise
  • Fitness Trackers
  • Humans
  • Self Report